Hi Afonso,<br>
<br>
Awesome, let me try this out.<br>
<br>
Also, I have to apologize, I should have lead with my use case first before diving straight into asking about waveform search results.<br>
<br>
I hope you have some other suggestions before I try the search table functions...basically, I need to measure time delays for my HDMI signals, but I am noticing the delay function is giving me erroneous readings depending on the waveforms.<br>
<br>
I have 2 main from sources I am measuring from, HPD and DDC SCL.<br>
When I am measuring from HPD Falling , I noticed if I set the 'to' waveforms (SCL, SDA, TMDS) to search backwards, the problem goes away<br>
<br>
However, if I measure from DDC SCL (should be last output, so look starting from the right) to compare it against the 'to' waveforms, I cannot get a good measurement. I think this is due to multiple edges occurring in both pre and post trigger.<br>
<br>
I can't seem to get this to work with the existing measurement system and have to use edge search to find the last edges of both 'from' and 'to' waveforms to calculate the timing difference.<br>
<br>
I am not sure if you have any suggests I can try before dealing with the search table solution? Preferably, if I can get away without setting the HPD measurements to backwards that would be a bonus as I am trying to main interoperability between different scope models and makers and some scopes don't have a backwards 'to' search function.<br>
<br>
Regards,<br>
Mike<br>
<br>